图片名称

2022.06.23

Jiangsu Yunuo Cooling Technology Co., Ltd. will introduce to you the description of the main structural characteristics of the closed cooling tower The closed cooling tower produced by the Cooling System Equipment Management Co., Ltd. is made of T2 deacidified copper tubes of China's international social standard, all of which are bare copper round tubes without fins to ensure its cooling effect. The closed cooling tower places the tubular heat exchanger in the tower, and ensures the cooling effect through the heat exchange of circulating air, spray water and circulating water. Because it is a closed cycle, it can ensure that the water quality is not polluted, well protect the efficient operation of the main equipment, and improve the service life. When the outside temperature is low, the sprinkler system can be stopped to save water. An enclosed cooling tower is derived from an evaporative cooler and is actually a heat exchanger that combines the performance of a water-cooled cooler and a conventional cooling tower. It is also a heat exchanger between a water cooler and an air cooler, so some manufacturers call it an "evaporative air cooler". In the closed cooling tower, the tubular heat exchanger is placed in the tower, and the cooling effect is ensured through the heat exchange of circulating air, spray water and circulating water. The equipment has strong anti-corrosion ability, small coefficient of thermal expansion and contraction, high heat transfer technology performance, high temperature working environment, will not be softened by organic matter, will not be penetrated by other harmful gases or liquids, can kill bacteria, and has a long service life . The main development of the closed cooling tower has different characteristics of the following data structures: ①The heart part of the closed cooling tower (deacidified copper tube cooling tower) The cooling equipment adopts the international standard t2 deacidified copper tube, and the fully bare copper tube has no fins to ensure the cooling effect. Strong corrosion resistance, small coefficient of thermal expansion and contraction, good heat transfer performance, high temperature resistance, anti-corrosion, will not be softened by organic matter, will not be penetrated by harmful gases or liquids, can be sterilized, and has a long service life. The new international coil design adopts a serpentine shape to ensure the inclination angle, so that the medium water in the cooler can be completely discharged when not in use, which avoids freezing in winter for northern customers and prolongs the service life of the cooler. ②High strength design The wind pressure resistance of the cooling tower body reaches 150Kgf/m2, and it can bear the load of the 12th grade prevention typhoon (wind speed influence is greater than 240 km/h), and the basic seismic intensity requirement reaches VIII degree (eighth grade). ③ Easy maintenance and safety (1) The tower body is provided with a flexible access door, and the tower body is provided with a spacious and safe passageway. (2) Hot-dip galvanized steel ladders are installed on the outer surface of the tower to facilitate the management, maintenance and overhaul of the fan and the upper part of the cooling tower structure. The above is the relevant content introduced to you by Jiangsu Yunuo Cooling Technology Co., Ltd.

图片名称

2022.06.23

Before the closed-circuit cooling tower is operated, two preliminary tasks of inspection and cleaning should be carried out. Its operation part should be checked in detail, and it can be carried out only after there is no problem. The following Wuxi Maytech Precision Machinery Co., Ltd. will introduce to you: enter the tower through the inspection door, sort out the sundries and sludge on the bottom basin, and check whether the pipeline is blocked. Use high-pressure water to wash the heat dissipation film and the soil of the bottom basin, and discharge the sewage through the drain port. The regular sewage discharge of the closed cooling tower mainly refers to removing the sludge, moss and corrosion products of the water receiving tray of the closed cooling tower, reducing the weight of the water receiving tray, preventing the blockage of the return water pipeline, reducing the turbidity rate of the circulating water, and strengthening the closed cooling. Tower refrigeration. It does not matter whether the water quality of the closed cooling tower is good or bad, the closed cooling tower blowdown can only temporarily sort out the obstacles in the tower, and the closed cooling tower packing and spray system have not been effectively sorted out. The fluid cooling tower is one of many high-tech products. Its cooling effect and service life are obvious to many customers, but this does not mean that protection? Protection is not important to it. In order to improve the operating efficiency of the fluid cooler, effective protection is very important. Many users should find that, after operating a fluid cooler for a period of time, the cooling power and speed of operation are significantly different from the power at the time of original purchase. The main reasons for low fluid cooling tower power include the effect of coil fouling on heat exchange power. Because the design of the closed cooling tower is also said to be fully enclosed, compared with the open cooling tower, we actually say that we should pay special attention to it itself. The reservoir, at the same time, the closed cooling tower can directly fill the water into the reservoir at a very large level. Moreover, from another perspective, I think the pool at the bottom of the open cooling tower is completely visible. At this time, people actually say that a series of predictions and replenishment of the water flow in the pool should be carried out, because this , I think it is very direct for the water replenishment of the open cooling tower. However, on the other hand, for the closed cooling tower, it actually means that there is no external pool. However, it is also said that a pool will be planned at the bottom of the closed cooling tower, and there is no automatic water replenishment equipment. . There is an air inlet grille installed on the bottom end of the closed cooling tower. Next, although it is said that there will be a pool below the grille, then we actually say that special attention should be paid to the top of the pool. In fact, it is also said that a cooling tower filler will be planned. and other related cooling components. For more companies that use closed cooling towers for the first time, how should water replenishment be carried out? First of all, we actually say that we should pay special attention to distinguishing the current water flow in the pool. According to this, from the surface layer of the closed cooling tower, the water supply line of the closed cooling tower is immediately marked. When the water volume of the closed cooling tower is less than the water level replenishment line, we should pay special attention immediately. The amount of water to expand the hydration.

图片名称

2022.06.23

The working process of the cooling tower: the working process of the circular counter-flow cooling tower is an example: the hot water from the main engine room passes through the water pump through the pipeline, the horizontal throat, the curved throat and the central throat with a certain pressure to press the circulating water to the water spreading system of the cooling tower. Inside, the water is evenly spread on the filler through the small holes on the water-spreading pipe; the dry low-H value air enters the tower from the bottom air net under the action of the fan, and the hot water flows through the surface of the filler to form a water film It exchanges heat with the air, and the hot air with high humidity and high han value is extracted from the top, and the cooling water drops into the bottom basin and flows into the host through the water outlet pipe. Under normal circumstances, the air entering the tower is dry air with low wet bulb temperature. There is obviously a difference in concentration of water molecules and a difference in kinetic energy pressure between water and air. When the fan is running, under the action of static pressure in the tower, The water molecules continuously evaporate into the air and become water vapor molecules, and the average kinetic energy of the remaining water molecules will decrease, thereby reducing the temperature of the circulating water. It can be seen from the above analysis that evaporative cooling has nothing to do with the temperature of the air (usually the dry bulb temperature) being lower or higher than the water temperature. As long as the water molecules can continuously evaporate into the air, the water temperature will decrease. However, the evaporation of water into the air does not go on endlessly. When the air in contact with the water is not saturated, the water molecules continuously evaporate into the air, but when the air on the water-air contact surface is saturated, the water molecules cannot evaporate, but are in a state of dynamic equilibrium. The number of water molecules evaporated is equal to the number of water molecules returned to the water from the air, and the water temperature remains the same. It can be seen from this that the drier the air in contact with the water, the easier the evaporation will proceed, and the easier the water temperature will be lowered.

图片名称
< 1234567 > proceed page
宇诺冷却

The Company is specialized in R&D, production and sales of a variety of water cooling products, such as closed cooling tower, crossflow tower, countercurrent tower, refrigerator, evaporative condenser, etc. In addition, the Company provides consulting of other relevant spare and accessory parts as well as technologies.

图片名称
图片名称

CONTACT:Manager Yang

图片名称

ADD: No. 69-2, Beihui Road, Huishan District, Wuxi City

图片名称
图片名称

Wechat QR code

Copyright © 2022 Jiangsu Yunuo Cooling Technology Co., Ltd.     苏ICP备11007656号-9     Powered by www.300.cn  SEO