Yunuo Cooling Technology will introduce the working principle of closed cooling tower to you. The complete set of closed cooling tower equipment consists of main engine, water tank, circulating water pump and electric control cabinet. The main engine is composed of shell, heat exchanger, fan, spray pump, water collector, water tank and pipeline valve and other components. During the working process, the cooling medium (soft water, oil or other liquid) is driven by the main circulating pump to circulate between the heat exchanger and the equipment to be cooled, and the spray water is evenly sprayed on the heat exchanger, on the outer surface of the heat exchanger A uniform water film is formed, and the cold air enters the tower from the air inlet below the tower body, and flows through the surface of the heat exchanger countercurrently with the spray water. Heat conduction and heat exchange of spray water evaporation and heat absorption, the saturated hot and humid air after absorbing heat is discharged into the atmosphere by the fan, and the rest of the spray water flows into the water tank at the bottom of the tower body, and is transported to the spray system by the water pump. In this way, the cooling medium in the heat exchanger is cooled down and cooled. There are two modes of operation for closed cooling towers. Air cooling, air cooling + spray. The switching of the two modes is automatically carried out by the electronic control system according to the requirements of the working conditions to achieve energy saving and consumption reduction. The main principle of the closed cooling tower is that the spray water evaporates on the outer wall of the coil to cool the cooling water flowing in the tube, and at the same time, the generated water vapor is taken away in time by the fan. A small part of the spray water evaporates, and the rest is collected by the chassis and recirculated. The higher temperature cooling water from the condenser is pressurized by the cooling water pump and sent to the cooling coil of the closed cooling tower. On the other hand, the water in the cooling tower chassis is pumped into the spray coil by the pipeline pump, and sprayed on the outer surface of the cooling coil to vaporize and absorb the heat of the cooling water in the coil, so that the temperature of the cooling water can be reduced. At the same time, by the suction effect of the fan installed on the water baffle, the air flows through the cooling coil from bottom to top, and exchanges sensible heat and latent heat with the spray water, which not only strengthens the cooling coil The surface heat is released, and the water vapor formed by evaporation can also be taken away in time to accelerate the evaporation of water and improve the cooling effect. During the working process of the closed working tower, the cooling medium (soft water, oil or other liquid) is driven by the main circulating pump to circulate between the heat exchanger and the equipment to be cooled, and the spray water is evenly sprayed on the heat exchanger. A uniform water film is formed on the outer surface of the heater. The cold air enters the tower from the air inlet below the tower body, and flows countercurrently with the spray water through the surface of the heat exchanger. There are two heat exchange methods in this process, namely, cold air and cooling. The heat conduction between the media and the heat exchange of the evaporation and heat absorption of the spray water, the saturated hot and humid air after absorbing the heat is discharged into the atmosphere by the fan, and the rest of the spray water flows into the water tank at the bottom of the tower body, and is transported to the spray by the water pump. system. In this way, the cooling medium in the heat exchanger is cooled down and cooled. The above is the relevant content introduced by Uno Cooling Technology.

图片名称

2022.06.23

Yunuo Cooling Technology will introduce several assembly methods of closed cooling towers to you. Closed cooling tower, referred to as closed cooling tower, (also called evaporative air cooler, closed cooling tower) places the tubular heat exchanger in the tower, through the heat exchange of circulating air, spray water and circulating water to ensure Cooling effect. Because it is a closed cycle, it can ensure that the water quality is not polluted, well protect the high standard operation of the main equipment, and improve the service life. When the outside temperature is low, the sprinkler system can be stopped to save water. Pushing the implementation of energy conservation and emission reduction policies and the increasing scarcity of water resources, closed cooling towers have been widely used in metallurgy, aviation, electric power, chemical industry, machinery, petroleum, food, plastic, rubber and other industries in recent years. The closed cooling tower originated from the evaporative cooler, which began in the middle of the last century, and gradually began to be used with the development of the chemical, metallurgical, and electronic industries. For evaporative cooling technology, as early as 250 BC, the ancient Egyptians already knew how to use water evaporation for cooling. In the last century, various countries have also carried out many aspects of research on evaporative cooling technology. In the 1970s, the emergence of the energy crisis made the application of evaporative cooling technology gradually paid attention. In the 1980s, when it was discovered that the catastrophic climate that posed a huge threat to human existence was related to the air-conditioning and refrigeration industry, passive cooling technologies such as evaporative cooling technology, which used natural conditions to obtain cooling capacity, developed rapidly. The American ASHRAE has established a technical committee called "evaporative cooling", which aims to promote the application of evaporative cooling technology, collect and publish data on the application, installation, operation and maintenance of evaporative cooling systems, publish specifications and standards, and affirm and reward Research on evaporative cooling, in order to promote the application of evaporative cooling equipment in the whole country. The closed cooling tower is then sent to the air through forced convection between the spray water and the air, and the heat transfer of the spray water to the air reduces energy consumption; the two-layer cooling method uses air-cooled evaporation to absorb heat, and the cooling efficiency is high; it can be directly cooled Water, oil, alcohol, quenching liquid, salt water and chemical liquid and other media, no medium loss, stable composition due to the use of closed cycle. The medium is not affected by the environment and will not pollute the environment. It is mainly composed of the latent heat of the spray water evaporation and the sensible heat exchange between the spray water and the air. Because the cooled fluid is a completely closed circulation activity between the cooling tower and the process equipment Therefore, there is no phenomenon that debris enters the cooling pipeline system, and then the pipeline is blocked; the soft water is circulated for cooling. At high temperature, there is never scale formation, which causes scaling in the cooling pipeline system. It is different from the general cooling tower in which the cooling fluid directly touches the air, so it is called a closed-circuit tower. Because the closed cooling tower is a fully enclosed circulating cooling, it occupies a small area, does not need to excavate a pool, is easy to locate, and saves water. The above is the relevant content introduced by Uno Cooling Technology.

图片名称

2022.06.23

Uno Cooling Technology will introduce the control analysis of cooling towers to you. The cooling tower is a comprehensive product integrating a variety of disciplines such as aerodynamics, thermodynamics, fluids, chemistry, biochemistry, materials science, static and dynamic structural mechanics, and processing technology. Water quality is a multi-variable function, and cooling is a multi-factor, multi-variable and multi-effect synthesis process The analysis of the fan energy-saving controller puts forward that the purpose of the fan energy-saving control management is to realize the closed-loop automatic control of the fan operation. The temperature of the water supply is preset according to the needs of production. The influence of the climate and meteorological environment on the water temperature and the influence of the change of the system heat exchange conditions on the water temperature are reflected in time by the measured value of the temperature sensor, and the energy consumption of the cooling equipment can be adjusted to stabilize. Water temperature, realize self-control energy saving. The purpose of the fan safety monitoring and management is to automatically detect the vibration, oil temperature, and oil level changes, display and record them, and at the same time, alarm and stop the fans whose detection value exceeds the limit, so as to In order to achieve the purpose of safe and stable operation of the fan, reduce or even eliminate the occurrence of damage to the fan. According to the actual situation of on-site management, it is determined that the three parameters of "fan vibration", "lubricating oil temperature" and "gearbox oil level" are important operating parameters to ensure the safety of the fan [3]. A total of 15 design parameters such as "measurement range", "measurement accuracy" and "inspection time" have been determined for R&D and production. The system was tested in the circulating water field once in September 1993, and was named "KR-939 Fan Safety Monitor". The cooling tower system uses multi-parameter combination probe technology, digital command coding technology and computer network management technology. The three-parameter combination probe is installed on the fixed seat of the berth ruler of the fan gear box, and its probe rod is directly inserted into the lubricating oil, which directly converts the oil temperature, berth and equipment vibration values ​​in the gear box into electrical signals, and transmits them to the remote control room. Fan safety monitor. Each safety monitor can be connected with 8 combined probes with a four-core cable to monitor the operating parameters of 8 fans in real time, and complete digital display at the same time. Over-limit alarm, over-limit shutdown and other multi-phase functions. After many tests and modification designs, it has been successfully applied to the equipment production site, and various parameters have reached the predetermined design requirements. To realize computer network control analysis, it can be connected with a management computer through a four-core communication cable (RS-422 standard serial interface), and the computer can be a general-purpose PC or an industrial computer. When equipped with the corresponding configuration monitoring and management software (DCS-900 software), it can realize network control with multiple KR-933 and KR-939 monitors. Ensure the safe operation of the fan According to field experience, the characteristics of the oil temperature, oil level and vibration curve of the fan in good condition are as follows: ①Oil temperature curve: It gradually rises and falls from the time of starting and stopping, and it becomes a smooth curve that approximates a straight line in about 1 hour. ② Berth curve: whether the machine is turned on or not, it should be approximately a horizontal straight line. ③ Vibration curve: In the power-on state, around a virtual straight line, make an irregular curve of up and down narrow oscillation. The above is the relevant content introduced by Uno Cooling Technology.

图片名称

2022.06.23

Yunuo Cooling Technology will introduce the closed cooling tower manufacturer to tell you what maintenance the closed cooling tower needs to do in winter. During the actual combination process of the closed cooling tower, it will have some structures of its own. From the perspective of the framework, basically some of their amplitudes are defined at 0.14 mm. If viewed from the wind tunnel, the entire closed cooling tower will be The relevant processing is carried out through the material of FRP. This kinetic energy can better recover some wind or air pipes, and can also make full use of some theories of airflow harmony, and can be combined with the time or measurement data of this project. Some practical situations are used to adopt the elliptic curve in all aspects. In this case, whether it is a curve or some other straight line of natural wind profile, it can relatively better eliminate some phenomena flowing in the air. In this way, some vortex areas will be avoided, and there will be more negative pressure areas in the airway core, and even they will greatly reduce the original use area in the entire negative pressure area, and the wind speed of the outlet section will be significantly more uniform. Some. For closed cooling tower manufacturers, when the circulating cooling system is used in the northern cold region, after a freezing accident occurs, it can cause production interruption, long repair and recovery time, and directly cause greater economic losses to users. Therefore, system antifreeze is an important If the closed cooling tower does not need to be operated in winter, the spray water and internal circulating water must be drained when it is shut down. The internal circulating water is recommended to be forced to be evacuated by compressed air, and the carbon steel tube heat exchanger is not recommended to be evacuated to prevent freezing. The problem of anti-freezing of closed-circuit cooling towers in the case of year-round operation. If the closed-type cooling towers that operate all the year round are equipped with an electronic control system, the number of cooling towers may change due to the load change of the main system, so it is also necessary to consider anti-freezing. question. Unused equipment can be evacuated before winter to prevent freezing. The antifreeze problem of the closed cooling tower is that the closed cooling tower has two parts: the spray water system and the internal circulating water system (softened water). The antifreeze problem of the spray water system is usually to add an electric heater in the water pool, which is generally turned on when the spray water is lower than 5°C, and stopped when the water is above 8°C. The temperature probe transmits the signal to the control cabinet to automatically control the start and stop of the electric heater. The power selection of the electric heater is determined according to the circulating water volume and the outside air temperature. For the antifreeze of the internal circulating water system, ethylene glycol solution can be added or electric heating equipment can be added. The freezing point temperature of the ethylene glycol solution is required to be selected below the local ultra-low temperature. For larger cooling systems, it is possible to consider digging a pool to pour the spray water into it, which can save electricity costs due to electric heating operation, and can also put medicines in the pool to improve the quality of the spray water. The above is the relevant content introduced by Uno Cooling Technology.

图片名称

2022.06.23

Uno Cooling Technology will give you an overview of closed cooling towers. The complete set of closed cooling tower equipment consists of main engine, water tank, circulating water pump and electric control cabinet. The main engine is composed of shell, heat exchanger, fan, spray pump, water collector, water tank and pipeline valve and other components. During the working process of the closed cooling tower, the cooling medium (soft water, oil or other liquid) is driven by the main circulating pump to circulate between the heat exchanger and the equipment to be cooled, and the spray water is evenly sprayed on the heat exchanger. A uniform water film is formed on the outer surface of the heater, and the cold air enters the tower from the air inlet below the tower body, and flows through the surface of the heat exchanger countercurrent to the spray water. There are two modes of operation for closed cooling towers. Air cooling, air cooling + spray. The switching of the two modes is automatically carried out by the electronic control system according to the requirements of the working conditions to achieve energy saving and consumption reduction. The main principle of the closed cooling tower is that the spray water evaporates on the outer wall of the coil to cool the cooling water flowing in the tube, and at the same time, the generated water vapor is taken away in time by the fan. A small part of the spray water evaporates, and the rest is collected by the chassis and recirculated. The higher temperature cooling water from the condenser is pressurized by the cooling water pump and sent to the cooling coil of the closed cooling tower. On the other hand, the water in the cooling tower chassis is pumped into the spray coil by the pipeline pump, and sprayed on the outer surface of the cooling coil to vaporize and absorb the heat of the cooling water in the coil, so that the temperature of the cooling water can be reduced. At the same time, by the suction effect of the fan installed on the water baffle, the air flows through the cooling coil from bottom to top, and exchanges sensible heat and latent heat with the spray water, which not only strengthens the cooling coil The surface heat is released, and the water vapor formed by evaporation can also be taken away in time to accelerate the evaporation of water and improve the cooling effect. Induction heating and metal smelting equipment for closed cooling towers, such as: high and medium frequency quenching equipment, medium frequency power supply and cooling of electric furnaces, induction diathermy furnaces, holding furnaces, etc. Cooling of circulating water for various reactors and condensers in the chemical industry. Cooling of large motors, diesel engines, rectifier equipment, electric welding equipment, hydraulic stations and continuous casting equipment, etc. Metal die-casting molds, injection molds and other large mold cooling. Cooling of industrial solutions, such as quenching liquid, electroplating liquid, etc. The cooling medium of the closed cooling tower is fully closed and circulated, which can prevent the sundries from entering the cooling pipeline system and the evaporation loss of the cooling medium. Use soft water as cooling medium, no scaling, no clogging of pipelines, and less failures. It adopts the dual cooling method of air cooling and spray water evaporation and heat absorption, and the cooling efficiency is high. The device is small in size, takes up little space, is convenient to move and place, and does not need to build a pool. Using automatic intelligent control, the cooling mode can be automatically changed according to the requirements of the working conditions, and the operation is simple and reliable. Wide range of uses, can directly cool quenching fluid, oil, alcohol and other media that have no corrosive effect on the heat exchanger, the medium has no loss, and the composition is stable. The above is the relevant content introduced by Uno Cooling Technology.

图片名称

2022.06.23

Yunuo Cooling Technology introduces the antifreeze of closed cooling towers to you. Closed cooling tower, referred to as closed cooling tower, (also called evaporative air cooler, closed cooling tower) places the tubular heat exchanger in the tower, through the heat exchange of circulating air, spray water and circulating water to ensure Cooling effect. Because it is a closed cycle, it can ensure that the water quality is not polluted, well protect the operation of the main equipment, and improve the service life. The closed cooling tower originated from the evaporative cooler, which began in the middle of the last century, and gradually began to be used with the development of the chemical, metallurgical, and electronic industries. In the 1980s, when it was discovered that the catastrophic climate that posed a huge threat to human existence was related to the air-conditioning and refrigeration industry, passive cooling technologies such as evaporative cooling technology, which used natural conditions to obtain cooling capacity, developed rapidly. The closed cooling tower originated from the evaporative cooler, which began in the middle of the last century, and gradually began to be used with the development of the chemical, metallurgical, and electronic industries. For evaporative cooling technology, as early as 250 BC, the ancient Egyptians already knew how to use water evaporation for cooling. In the last century, various countries have also carried out many aspects of research on evaporative cooling technology. In the 1970s, the emergence of the energy crisis made the application of evaporative cooling technology gradually paid attention. The American ASHRAE has established a technical committee called "evaporative cooling", which aims to promote the application of evaporative cooling technology, collect and publish data on the application, installation, operation and maintenance of evaporative cooling systems, publish specifications and standards, and affirm and reward Research on evaporative cooling, in order to promote the application of evaporative cooling equipment in the whole country. Antifreeze measures for occasions that are basically not used in winter If the closed cooling tower does not need to be operated in winter, the spray water and internal circulating water must be drained when it is shut down. The cooling tower adopts a three-dimensional inclined structure in the design of the heat exchanger to ensure smooth flow of water and clean emptying. The top of the heat exchanger is provided with an air valve structure, and compressed air can be introduced to assist in emptying if necessary. Antifreeze problem in occasions running in some time periods The antifreeze of the closed cooling tower has two parts: the spray water system and the internal circulating water system (softened water). For the antifreeze problem of the spray water system, an electric heater is usually added in the water sump, which is generally turned on when the spray water is lower than 5 ℃, and stopped when the temperature is above 8 ℃. The temperature probe transmits the signal to the control cabinet to automatically control the start and stop of the electric heater. The power selection of the electric heater is determined according to the circulating water volume and the outside air temperature. For the antifreeze of the internal circulating water system, ethylene glycol solution can be added or electric heating equipment can be added. The formula of ethylene glycol solution can be consulted by our company. For larger cooling systems, it is possible to consider digging a pool to pour the spray water into it, which can save electricity costs due to electric heating operation, and can also put medicines in the pool to improve the quality of the spray water. If the closed cooling tower is equipped with an electronic control system, the number of cooling towers may change due to the load change of the main system, so the problem of antifreeze should also be considered. With the continuous development of science and technology, closed cooling towers will inevitably usher in greater development and application space. The above is the relevant content introduced by Uno Cooling Technology.

图片名称
< 1234567 > proceed page
宇诺冷却

The Company is specialized in R&D, production and sales of a variety of water cooling products, such as closed cooling tower, crossflow tower, countercurrent tower, refrigerator, evaporative condenser, etc. In addition, the Company provides consulting of other relevant spare and accessory parts as well as technologies.