图片名称
+
  • 3-1(1).jpg

YBN countercurrent closed cooling tower

Category:


Features

Product performance  1. The product adopts countercurrent cooling. There are few dead zones of heat dissipation, and the heat exchange efficiency is high.  2. The professional and efficient water receiver can control the operation drifting ratio ≤ 0.001%.  3. The high-air drum design guarantees that the air volume for running of the equipment can meet the heat dissipation demand.  4. Compared with other forms of cooling towers, this product covers a smaller land area and can meet users' spatial demand.  5. Closed circulating is applied to the box, preventing sundries entering into the tower body. Otherwise, the sprayer will be blocked.  6. The anti-freeze and energy-saving cooler can guarantee the circulating water is drained thoroughly, in case of freeze-off when the temperature in the northern region is relatively low.  7. Double-loop circulation can be designed according to the users' equipment demand, so that even one loop of circulation fails, the other loop of circulation can run normally.  8. The unit configured with automatic digital display is beautiful and elegant, feasible and easy to operate and maintain. 
Message

Product Details


Product performance 

1. The product adopts countercurrent cooling. There are few dead zones of heat dissipation, and the heat exchange efficiency is high. 
2. The professional and efficient water receiver can control the operation drifting ratio ≤ 0.001%. 
3. The high-air drum design guarantees that the air volume for running of the equipment can meet the heat dissipation demand. 
4. Compared with other forms of cooling towers, this product covers a smaller land area and can meet users' spatial demand. 
5. Closed circulating is applied to the box, preventing sundries entering into the tower body. Otherwise, the sprayer will be blocked. 
6. The anti-freeze and energy-saving cooler can guarantee the circulating water is drained thoroughly, in case of freeze-off when the temperature in the northern region is relatively low. 
7. Double-loop circulation can be designed according to the users' equipment demand, so that even one loop of circulation fails, the other loop of circulation can run normally. 
8. The unit configured with automatic digital display is beautiful and elegant, feasible and easy to operate and maintain. 

 

YBN Counterflow Closed Cooling Tower Parameter Table

Model

Cooling amount

Fan

Spray pump

Weight (split)

Overall dimension
(length*width*height) mm

Water inlet and
outlet caliber

Water supplementation
opening caliber

Sewage drainage
opening caliber

Type Kcal Kw

Power Kw

Air volume m3/h

Power Kw

Flow rate T/h

Lift m

Conveying Kg

Operation Kg

length x width x total height

DN DN DN
YBN-01 50000 58 1.1x1 16000 1.1 45 5 500 800 1550x1150x2500 50 20 25
YBN-02 75000 87 2.2x1 28000 680 1050 2000x1150x2600 50 20 25
YBN-03 100000 116 1.1x2 32000 750 1200 2300x1150x2600 65 20 25
YBN-04 125000 145 1.1x2 32000 1.5 65 5 850 1390 2850x1150x2800 65 25 32
YBN-05 150000 174 1.5x2 40000 1200 2700 2850x1150x2800 80 25 32
YBN-06 200000 233 2.2x2 56000 2.2 100 5 1550 3200 2850x1600x2960 80 25 32
YBN-07 250000 291 2.2x2 56000 1680 3450 2850x1600x2960 80 25 32
YBN-08 300000 348 2.2x2 60000 1850 3700 3650x1600x3230 100 25 32
YBN-09 350000 407 3x2 80000 3 150 5 2000 4000 3650x1600x3350 100 25 32
YBN-10 400000 465 3x2 86000 2350 4560 3650x1900x3570 125 32 40
YBN-11 500000 581 3x2 100000 5.5 230 6 2790 5380 4300x1900x3600 100x2 32 40
YBN-12 625000 727 4x2 120000 3200 6660 4300x2200x3720 100x2 32 40
YBN-13 750000 872 5.5x2 160000 7.5 280 6 3800 8000 5000x2200x4100 125x2 40 50
YBN-14 900000 1046 7.5x2 192000 4250 9300 5300x2400x4100 125x2 40 50
YBN-15 1000000 1163 7.5x2 230000 3x2 300 5 5000 11200 5300x2700x4420 150x2 40 50
YBN-16 1150000 1337 7.5x2 260000 5220 12500 5300x2900x4620 150x2 40 50
YBN-17 1250000 1453 7.5x2 260000 5.5x2 460 6 5800 13000 6300x2900x4620 150x2 40 50
YBN-18 1400000 1628 11x2 280000 6290 13900 6300x3000x4910 150x2 50 65
YBN-19 1500000 1744 11x2 280000 7.5x2 560 6 6800 14900 7000x3000x5160 200x2 50 65
YBN-20 1750000 2034 15x2 360000 7500 15500 7000x3200x5260 200x2 50 65
YBN-21 2000000 2326 15x2 400000 5.5x2 460 6 8260 16360 7800x3200x5560 200x2 50 65
YBN-22 2250000 2616 18.5x2 490000 9210 18200 8200x3200x5560 200x2 50 65
YBN-23 2500000 2907 18.5x2 540000 7.5x2 560 6 9950 19950 9100x3400x5560 200x2 50 65

Note: the change in parameters arising from the change in the equipment model may occur without prior notice. The specific parameters are subject to our scheme.

ONLINE MESSAGE

SUBMIT
宇诺冷却

The Company is specialized in R&D, production and sales of a variety of water cooling products, such as closed cooling tower, crossflow tower, countercurrent tower, refrigerator, evaporative condenser, etc. In addition, the Company provides consulting of other relevant spare and accessory parts as well as technologies.

图片名称
图片名称

CONTACT:Manager Yang

图片名称

ADD: No. 69-2, Beihui Road, Huishan District, Wuxi City

图片名称
图片名称

Wechat QR code

Copyright © 2022 Jiangsu Yunuo Cooling Technology Co., Ltd.     苏ICP备11007656号-9     Powered by www.300.cn  SEO