图片名称
+
  • 4-1(1).jpg

YKH square crossflow open cooling tower

Category:


Features

Product performance  1. In the high temperature difference (HIGHRANGE), that is, the temperature difference between hot and cold water exceeds 18 degrees, because the hot water needs to reduce the temperature by more than 18 degrees in a short time, it needs sufficient time to contact the air with the filler, so the filler should be is very high. (actually equivalent to two, three cooling); 2. Since the wind and water of the cross-flow tower are in the cross-flow direction, the resistance is only related to the diameter and depth, and has nothing to do with the height, so it can theoretically be very high; 3. The packing of the countercurrent tower cannot be made very high, and the wind and water convection, generally above 1.5M, may cause air resistance. For example, color coating and galvanizing cooling in steel mills, and cross-flow towers can be used in rubber factories where hot water needs to be reduced from 55 degrees to 35 degrees or lower; 4. The water tower made of SKS steel has a packing height of 5.5M and a cooling temperature difference of 25 degrees; it is the papermaking process of APP Jinguang Group, using a 400T/H single-cell cross-flow tower with a packing height of 15M;
Message

Product Details


Product performance 

1. In the high temperature difference (HIGHRANGE), that is, the temperature difference between hot and cold water exceeds 18 degrees, because the hot water needs to reduce the temperature by more than 18 degrees in a short time, it needs sufficient time to contact the air with the filler, so the filler should be is very high. (actually equivalent to two, three cooling);
2. Since the wind and water of the cross-flow tower are in the cross-flow direction, the resistance is only related to the diameter and depth, and has nothing to do with the height, so it can theoretically be very high;
3. The packing of the countercurrent tower cannot be made very high, and the wind and water convection, generally above 1.5M, may cause air resistance. For example, color coating and galvanizing cooling in steel mills, and cross-flow towers can be used in rubber factories where hot water needs to be reduced from 55 degrees to 35 degrees or lower;
4. The water tower made of SKS steel has a packing height of 5.5M and a cooling temperature difference of 25 degrees; it is the papermaking process of APP Jinguang Group, using a 400T/H single-cell cross-flow tower with a packing height of 15M;
5. In the case of sewage, the cross-flow tower can use grid material, and it can be easily cleaned at any time without stopping; although the counter-flow tower can use grid packing, there are problems in the management, and in practical projects, sewage is often With high temperature, the cross-flow tower can be used in two ways.

 

YKH Square Crossflow Open Cooling Tower Parameter Table 

Parameter  water quantity m3/h  model

Standard model

Overall dimension

Air volume

Fan blade diameter

Motor power

Tower lift

Adapter caliber

Weight

Noise decibel

37~32℃

Length

(L)

(W)

(H)

Water inlet and outlet

Overflow

Sewage drainage

Water supplementation

Dead weight

Operation

Standard point

28℃ mm mm mm m3/h mm KW mH2O DNmm DNmm DNmm DNmm Kg Kg DN
YKH-50 50 1500 3200 3200 33000 1200 1.5 3.8 100 50 40 20 670 1475 58
YKH-65 65 1880 3200 3200 40000 1200 2.2 3.8 100 50 40 20 740 1685 58
YKH-80 80 1880 3400 3200 56000 1500 3 3.8 125 65 40 20 8802 2040 59
YKH-100 100 2180 3400 3700 60000 1500 3 4.2 125 65 40 20 1150 2350 59
YKH-125 125 2180 3800 3700 79000 1800 4 4.2 150 80 40 20 1250 2550 59
YKH-150 150 2680 3800 3700 100000 1800 4 4.2 150 80 40 20 1350 2850 59
YKH-175 175 2680 4200 3700 105000 2200 5.5 4.2 200 80 40 20 1520 3130 60
YKH-200 200 2680 4200 4500 125000 2200 7.5 5.1 200 80 40 25 1620 3770 60
YKH-225 225 3000 4200 4500 130000 2200 7.5 5.1 200 80 40 25 2080 4300 60
YKH-250 250 3000 4500 4500 175000 2500 7.5 5.1 200 80 40 25 2200 4870 61
YKH-300 300 3000 5000 4500 185000 2500 7.5 5.1 200 80 40 25 2550 5300 61
YKH-350 350 3300 5500 4800 200000 2950 11 5.4 250 80 40 40 2850 6200 61
YKH-400 400 3300 5500 5400 220000 2950 11 6 250 80 40 40 3250 6600 62
YKH-450 450 3800 5550 5400 235000 2950 11 6 250 80 50 40 3550 7400 62
YKH-500 500 3800 6000 5600 305000 3400 15 6.2 300 80 50 40 4050 8200 63
YKH-600 600 4600 6000 5600 335000 3400 15 6.2 300 80 50 50 4650 9800 63
YKH-700 700 4600 6200 6000 395000 3600 18.5 6.5 300 80 50 50 5050 10500 64
YKH-800 800 5100 6200 6000 455000 3600 22 6.5 300 80 50 50 5450 115000 65

Note: the change in parameters arising from the change in the equipment model may occur without prior notice. The specific parameters are subject to our scheme.

Steel open tower, parameters on request.

ONLINE MESSAGE

SUBMIT
宇诺冷却

The Company is specialized in R&D, production and sales of a variety of water cooling products, such as closed cooling tower, crossflow tower, countercurrent tower, refrigerator, evaporative condenser, etc. In addition, the Company provides consulting of other relevant spare and accessory parts as well as technologies.

图片名称
图片名称

CONTACT:Manager Yang

图片名称

ADD: No. 69-2, Beihui Road, Huishan District, Wuxi City

图片名称
图片名称

Wechat QR code

Copyright © 2022 Jiangsu Yunuo Cooling Technology Co., Ltd.     苏ICP备11007656号-9     Powered by www.300.cn  SEO