There is a lot of floating water in the cooling tower. What are the control measures we can take?
2022-06-23
Jiangsu Yunuo Cooling Technology will introduce to you the control measures that we can take for a lot of floating water in cooling towers.
As a kind of cooling equipment that is particularly popular in recent years, cooling tower has the significant advantages of high efficiency, low energy consumption, high cost performance, and its flow rate drift rate is controlled within a reasonable range. Compared with the open cooling tower, the work efficiency is improved, the cost is reduced, and it is environmentally friendly. Several causes and control measures for a lot of floating water in closed cooling towers, there are problems with the water collector. There is a water collector at the bottom of the fan, which is specially designed to recover the water in the flowing gas. If the amount of floating water increases, it is necessary to first consider the difficulty of the water collector. If the new equipment is obviously not suitable for the equipment collector ring, the internal gap is large, and the viewpoint is not suitable. When the equipment is outdated, the aging of the collector should be considered. Aging will cause water accumulation in the water collector, local damage, unstable and loose installation standards. As a result, the catchment volume is reduced and the drifting speed is accelerated. The fan has a large air volume. The fan power is large, the wind force is large, and the air volume of the selected supporting equipment is obviously fast. After the hot and humid gas passes through the water collector, the moisture in the gas will be quickly discharged. If not collected immediately, a lot of cooling circulating water will be pumped out through cooling water. fan. In this case, consider removing the fan to adjust the viewing angle of the fan blades. Fan speed is too low. It is well known that closed cooling towers have intake grills on the side or at the bottom. Air enters and gas inflow occurs. If the air volume of the fan is small, the air intake force to generate the airflow will be larger; if it is smaller, the water in the hot and humid air will quickly move out of the grille, which will also cause a high drift rate. Excessive water spray from the bottom. The closed cooling tower has a water storage tank at the bottom, and this water storage tank is close to the air intake grille. If there is a large amount of water in the pool, the rapidly descending spray can land on the surface of the pool and cause splashing. Water, splashing water droplets will immediately penetrate the grille to the outside of the enclosed cooling tower. According to this, we generally establish a water supply line first, and then supply the spray water when the amount of water spray is lower than the water supply line for reasonable control.